Search results for "electromagnetic [effect]"
showing 10 items of 555 documents
Personal exposure to radio-frequency electromagnetic fields in Europe: Is there a generation gap?
2018
Background: Exposure to radiofrequency electromagnetic fields (RF-EMF) from mobile communication technologies is changing rapidly. To characterize sources and associated variability, we studied the differences and correlations in exposure patterns between children aged 8 to 18 and their parents, over the course of the day, by age, by activity pattern, and for different metrics of exposure. Methods: Using portable RF-EMF measurement devices, we collected simultaneous real-time personal measurements of RF-EMF over 24 to 72 h in 294 parent-child pairs from Denmark, the Netherlands, Slovenia, Switzerland, and Spain. The devices measured the power flux density (mW/m(2)) in 16 different frequency…
Heavy metal exposure in patients suffering from electromagnetic hypersensitivity
2009
Abstract Background Risks from electromagnetic devices are of considerable concern. Electrohypersensitive (EHS) persons attribute a variety of rather unspecific symptoms to the exposure to electromagnetic fields. The pathophysiology of EHS is unknown and therapy remains a challenge. Objectives Heavy metal load has been discussed as a potential factor in the symptomatology of EHS patients. The main objective of the study was to test the hypothesis of a link between EHS and heavy metal exposure. Methods We measured lead, mercury and cadmium concentrations in the blood of 132 patients ( n = 42 males and n = 90 females) and 101 controls ( n = 34 males and n = 67 females). Results Our result…
Effectiveness of platinum wire microcoils for venous occlusion: A study on patients treated for venogenic impotence
1994
The purpose of this study was to determine the effectiveness of venous occlusions achieved by embolization with platinum microwire coils. Follow-up venographies in 19 patients, 1-20 months (average 8 months) after coil embolizations, were evaluated. Twenty-eight of 126 (22.2%) coil embolizations were found to be patent. Coils which had not formed or partially formed upon embolization had a patency/recanalization rate of 37.5% (12/32). Among coils which had formed nearly completely or completely only 16 of 95 (17%) showed venous patency. As coil embolization had been augmented by sclerotherapy in all patients, the effectiveness of long-term venous occlusion by platinum wire coils alone is pr…
No effects of mobile phone use on cortical auditory change-detection in children: an ERP study
2010
We investigated the effect of mobile phone use on the auditory sensory memory in children. Auditory event-related potentials (ERPs), P1, N2, mismatch negativity (MMN), and P3a, were recorded from 17 children, aged 11–12 years, in the recently developed multi-feature paradigm. This paradigm allows one to determine the neural change-detection profile consisting of several different types of acoustic changes. During the recording, an ordinary GSM (Global System for Mobile Communications) mobile phone emitting 902 MHz (pulsed at 217 Hz) electromagnetic field (EMF) was placed on the ear, over the left or right temporal area (SAR1g = 1.14 W/kg, SAR10g = 0.82 W/kg, peak value = 1.21 W/kg). The EMF…
1 Hz repetitive transcranial magnetic stimulation of the unaffected hemisphere ameliorates contralesional visuospatial neglect in humans
2002
The aim of the study was to investigate whether low-frequency repetitive transcranial magnetic stimulation (rTMS) over the unaffected hemisphere can ameliorate visuospatial neglect. We treated three right brain damaged patients with left neglect. 900 pulses (1 Hz frequency) were given over left posterior parietal cortex every other day for 2 weeks. Patients performed a computerized task requiring length judgement of prebisected lines, tachistoscopically presented for 150 ms. With respect to rTMS the task was given 15 days before, at the beginning, at the end and 15 days after. At these times patients performed also line bisection and clock drawing tasks. rTMS induced a significant improveme…
A case study of Primary Progressive Aphasia: improvement on verbs after rTMS treatment.
2006
This case-report shows that high frequency repetitive Transcranial Magnetic Stimulation (hf-rTMS), applied to the left prefrontal cortex, may improve the linguistic skills in Primary Progressive Aphasia (PPA). The patient's performance was evaluated on a battery of language production and memory span tasks, before and after two hf-rTMS treatments and one SHAM treatment. We observed a significant and lasting improvement of the patient's performance on verb production following the application of hf-rTMS versus Baseline and SHAM conditions. This finding suggests that hf-rTMS may directly strengthen the neural connections within an area of metabolic dysfunction and encourages the use of rTMS a…
Transcranial magnetic resonance-guided focused ultrasound surgery at 1.5T: a technical note.
2019
Magnetic resonance-guided focused ultrasound is one of the emerging non-invasive technologies offering both image guidance and thermal monitoring. In recent years transcranial application of this technology is starting to impact heavily the neuroscience field. We present here the imaging protocol and the technological methods successfully used with a transcranial magnetic resonance-guided focused ultrasound system certified for clinical treatments of functional neurological disorders, integrated for the first time with a 1.5T magnetic resonance scanner. Compared to the body radiofrequency coil (the one commonly used with transcranial magnetic resonance-guided focused ultrasound system integ…
High frequency modeling technique for three phase power electronics module
2015
Nowadays, the high integrated power electronics modules (PMs), characterized by high speed, low loss and hard ware miniaturization, represent a new technology that meets the emerging demands of many applications, such us vehicle and home appliance, renewable energy sources in smart grid. The integration process and the high switching speeds increase the PM electromagnetic emissions that can create electromagnetic interference (EMI) with electric/electronic devices near the PMs. For this reason, electromagnetic compatibility (EMC) have to be carefully considered, yet in the design phase, to guarantee the reliability of PM systems. In this paper a method to develop a high frequency (HF) model…
Characterization of Different Cable Ferrite Materials to Reduce the Electromagnetic Noise in the 2–150 kHz Frequency Range
2018
The gap of standardization for conducted and field coupled electromagnetic interferences (EMI) in the 2–150 kHz frequency range can lead to Electromagnetic Compatibility (EMC) problems. This is caused by power systems such as Pulse Width Modulation (PWM) controlled rectifiers, photovoltaic inverters or charging battery units in electric vehicles. This is a very important frequency spectral due to interferences generated in a wide range of devices and, specifically, communication problems in the new technologies and devices incorporated to the traditional grid to convert it into a Smart Grid. Consequently, it is necessary to provide new solutions to attenuate this kind of interference, which…